Ansul Autopulse IQ-636X-2

The AUTOPULSE IQ-636X-2 Agent Releasing Control Panel is designed with modularity and easy system planning. The AUTOPULSE IQ-636X-2 can be configured with just a few devices for small building applications or for a large campus or high-rise application. Simply add additional peripheral equipment to suit the application. 

request information »

  • AUTOPULSE IQ-636X-2 Kit Contains:
    • (1) 434953 AUTOPULSE IQ-636X-2 CPU
    • (1) 433614 Black Display Dress Panel-2 CP-DISP2
    • (1) 433613 KDM-R2  
    • (2) 432794 Black Module Dress Plate BMP-1
    • (1) 433526 CAB A4R Red  
    • (1) 433522 CAB A4R Door, Lock and Keys – Red  
    • (1) 434955 Battery Dress Plate BP2-4
  • Certified for seismic applications when used with the appropriate seismic mounting kit
  • Approved for Marine applications when used with listed compatible equipment
  • One, expandable to two, isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7
  • Up to 159 detectors (any mix of ion, photo, thermal, or multi-sensor) and 159 modules (NO manual stations, two-wire smoke, notification, or relay) per SLC. 318 devices per loop/636 total
  • A 2x40 character display or optional 16x40 character display
  • Four Notification Appliance Circuits (NAC) providing 1.5 Amps each with built-in Class A/B wiring options. Selectable System Sensor, Wheelock, or Gentex strobe synchronization
  • Built-in Alarm, Trouble, and Supervisory relays
  • VeriFire® Tools online or offline programming utility. Upload/Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware
  • Autoprogramming and Walk Test reports
  • Optional universal 636-point DACT
  • Up to 32 remote annunciators can be added on EIA-485 bus
  • EIA-485 annunciators, including custom graphics
  • EIA-232 port for printing or PC connection
  • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file
  • Alarm Verification selection per point, with tally
  • Positive Alarm Sequence (PAS) presignal
  • Silence inhibit and Auto Silence timer options
  • March time/temporal/California two-stage coding/strobe synchronization
  • Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate
  • Full QWERTY keypad
  • Charger for up to 18-200 amp hours of standby power
  • Non-alarm points for lower priority functions
  • Remote ACK/Signal Silence/System Reset/Drill via monitor modules
  • Automatic time control functions, with holiday exceptions
  • Extensive, built-in transient protection
  • Powerful Boolean logic equations
  • USB port for PC connection
  • These listings and approvals apply to the basic AUTOPULSE IQ-636X-2 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. The AUTOPULSE IQ-636X-2 complies with UL Standards 864, 9th Edition (Fire). It is designed to meet NFPA 72 Local, Auxiliary, Remote Station, and Proprietary (not applicable for FM) Fire System Requirements
    • UL Listed S4935
    • ULC Listed S4935
    • FM Approved
    • MEA 128-07-E
    • California State Fire Marshall 7165-0595:117
    • FDNY COA#6043
    • OSHPD - .OSP-0072-10
    • City of Chicago
    • City and County of Denver
    • CCCF Listed
    • When used with the MARINE-EQ, appropriate seismic bracket, and marine approved devices, these agent releasing control panels are approved by the following agencies
      • US Coast Guard 161.002/A50/0 (Standard 46 CFR)

fm-appoved-logo.jpg  ul-listed-logo.jpg

You may also be interested in...

recent news

Jul 5,2023

Why you should consider hiring Suppression Systems, Inc

Why you should consider hiring Suppression Systems, Inc...Read More »

Jun 22,2023

Lithium-Ion Batteries

Lithium-Ion Batteries...Read More »

questions? like to schedule a consultation?

Contact us!
person